USR-CANET200 Industrial CAN to Ethernet Converter

Industrial CAN to Ethernet Converter, USR-CANE200 can realize data communication between CAN and network server. Integrated two CAN port and one Ethernet port,TCP/IP protocol,users can easily interconnect between CAN-bus and Ethernet

  • Increase communication distance expand CAN network
  • CAN /Ethernet/RS485 Transfer among three networks
  • Support two sockets to connect to two servers

Industrial CAN to Ethernet Converter – USR-CANET200

CAN relaying

  • Increase communication distance
  • Expand CAN network

Transfer among three networks

  • CAN transfer to Ethernet
  • CAN transfer to RS485
  • Ethernet transfer to RS485

Dual Socket

Support two sockets to connect to two servers.

Product Description

Industrial CAN to Ethernet Converter, USR-CANE200 can realize data communication between CAN and network server. Integrated two CAN port and one Ethernet port,TCP/IP protocol,users can easily interconnect between CAN-bus and Ethernet.

Character

1)Industrial solution,working temp.-40~85℃
2)two CAN port and one Ethernet port,TCP/IP protocol,extend the CAN network
3)Transfers among three networks: CAN to Ethernet,CAN to RS485, Ethernet to RS485
4) Supports dual sockets to connect to two servers,one socket to control,another socket to manage
5) Protection:Power interface anti-reverse, CAN interface surge and digital isolation protection
6) Hardware and software watchdog, connects stable

Basic Functions

Bidirectional transmision among CAN1 interface, CAN2 interface, RS485 interface and Ethernet interface.

Support CAN relaying function(Bidirectional transmission between CAN1 and CAN2) and CAN to RS485 function.

Hardware Interface

Functional Diagram

Wide temperature range

  • Wide temperature range
  • Industrial grade design which can meet temperature and voltage demand in various application fields.

Interface Protection

EFT

ESD

Watch-Dog

Application

Charging Pile Solution

  • Expand charging pile management scope to save cost.
  • Extend communication distance through CAN relaying function.
  • Real-time monitoring for all charging piles status to control the status of the project timely.

Building Control Solution

  • Industrial grade design which can adapt to outdoors harsh environment.
  • Flexible application:Transfer among CAN interface, Ethernet interface and RS485.
  • Take real-time information of different building into account and transmit these information to remote server to make overall plans.

Mine Monitoring Solution

  • Realize real-time transmission of mine data such as pressure, dust, humidity temperature to ensure production safety.
  • Watch-dog mechanism which can bring powerful anti-interface capability.
  • Extend system communication distance through CAN relaying function which can provide convenience on arranging monitoring node.

Specifications

ParameterValue
Hardware parameter
Working voltage

DC 5~36V

Working current

Average 26mA@36V
Average 56mA@12V
Average 124mA@5V
Power supply protection

Power supply surge: Level three.
Group pulse: Level three.
Ethernet interface specification

RJ45, 10/100Mbps, support Auto-MDI/MDIX.

Ethernet interface protection

1.5KV electromagnetic isolation

Serial port

RS485

Serial port baud rate

600~115.2K(bps)
CAN baud rate

10K~1M(bps)

CAN work mode

Basic, loopback

CAN protection

Power supply isolation, signal isolation

Software parameter
Network protocol

IPV4, TCP/UDP

How to get IP

Static IP, DHCP

Configuration method

Web Server, serial/network AT command

TCP Server connection

Support at most four TCP Client connections; serial server only support one Client connection

CAN receiving capability

8000 frames every second(Every way)

CAN transmitting capability

8000 frames every second(Every way)

Network cache

Transmitting: 16K bytes; receiving: 16K bytes

CAN cache

Transmitting: two hundred complete data packets(Every way); receiving: two hundred complete data packets(Every way)

Serial cache

Transmitting: 2K bytes; receiving: 2K bytes

Flow control

Don’t support

Heartbeat packet

CAN: Support user editable heartbeat packet(CAN data packet that conforms to transparent transmission protocol).
Serial port: Support user editable heartbeat packet
Identity packet

CAN: Support user editable, MAC, USR Cloud identity packet.
Serial port: Support user editable, MAC, USR Cloud identity packet
Average transmission delay

<20 ms

Request a Quote