USR-M511Modbus Gateway, Modbus RTU to TCP

USR-M511 is Modbus gateways that query Modbus RTU/ASCII slave and display data in internal webpage. It also supports reply the querying from Modbus TCP Master. USR-M511 provides a flexible method to control and monitor your Modbus RTU/ASCII devices.

  • Support RS232/RS485 or RS422
  • Ethernet accessory
  • Internal webpage to control and monitor
  • Auto query Modbus RTU/ASCII Slave device

Introduction

USR-M511 is Modbus gateway that query Modbus RTU/ASCII slave and display data in internal webpage. It also supports reply the querying from Modbus TCP Master. USR-M511 provides a flexible method to control and monitor your Modbus RTU/ASCII devices.

Industrial Modbus Gateway

  • Modbus RTU/ASCII <===> Mobus TCP
  • No timeout for frequent queries by 16 masters
  • The target address of 8 slaves can be set arbitrarily
  • Supports Modbus slave management

Features

  • Support RS232/RS485 or RS422.
  • Ethernet accessory.
  • Internal webpage to control and monitor.
  • Auto query Modbus RTU/ASCII Slave device.
  • Modbus RTU/ASCII to Modbus TCP.
  • 10/100Mbps ethernet interface, support Auto-MDI/MDIX.
  • Baud rate support 600bps~230.4K bps; Support None, Odd, Even, Mark, Space.
  • Support hardware Reload.
  • Support Static IP/DHCP.
  • Support hardware Reload.

Basic Function

No timeout for frequent queries by 16 masters

8 Master Modes

Structure

Application

Unmanned Weighing Data Acquisition Solution

Connect the Modbus gateway to the control center, and connect the various switched through the Modbus protocol to the Ethernet network. Support the control camera capture, weighing instrument, LED screen and other equipment and other equipment on the unified management of data.

Intelligent Traffic Monitoring Solution

Connect the Modbus gateway to the control center, and convert it into an Ethernet via Modbus protocol.Used to traffic data collection and processing.

Industrial Automation Solution

Connect the Modbus Gateway to the control center, then the sensor, controller, memory and other equipment will be connected to the Ethernet network via the Modbus protocol. Used to realize the industrial automation process and the field management.

Specifications

ParameterValue
Certification
Size86*81*24mm(L*W*H)
Temperature
Working Temp -40~85℃
Storage Temp -45~105℃
Humidity
Working Humidity 5%~95%
Storage Humidity 5%~95%
Power Supply
Working Voltage DC 5~36 V
Working Current 95mA@5V
Serial Port RS232/RS485/RS422
Network Protocol IPV4, TCP/UDP
IP Access Method Static IP, DHCP
DNS, Modbus, Customize Webpage Support